XAK supports selection and integration of the Inatech product family for linear and rotary position feedback — magnetic scales, encoder rings, readheads and drawing-based sensing components.
The magnetic scale or ring carries the position pattern; the readhead detects the changing magnetic field and provides signals to the customer’s control or measurement electronics.

TR10, TR12, TR20 and TR50 pole-pitch options for linear position-encoding layouts and cut-to-length designs.

Short-scale formats, custom lengths and reference-pattern options for compact mechanisms and absolute encoder discussions.

Incremental multipole rings and dual-track absolute ring formats for rotary position feedback.

Non-contact readheads with integrated conversion and digital A/B quadrature output for compatible incremental scales.
Choose the pole pitch together with the readhead and target signal interface. Do not select it as a stand-alone indicator of system resolution.
| Series | Pole pitch | Supplier-listed common format | Selection note |
|---|---|---|---|
| TR10 | 1.0 mm | Rolled scale; 50 m length format | For compatible 1 mm pole-pitch readhead designs. |
| TR12 | 1.2 mm | Rolled scale; 50 m length format | Match the exact readhead and interpolation electronics. |
| TR20 | 2.0 mm | Rolled scale; 50 m length format | Common option for incremental linear measurement layouts. |
| TR50 | 5.0 mm | Rolled scale; 50 m length format | Use only with a compatible sensor and signal design. |
Shared supplier-listed data for the rolled-scale family: magnetization accuracy ±0.03 mm; widths 5, 6, 8, 10 and 20 mm; thicknesses 0.5, 1.0, 1.5 and 2.0 mm; operating temperature −20 to +70°C; storage temperature −40 to +90°C. Magnetization accuracy is not the accuracy of a complete measurement system.
The examples below help define an RFQ. Other dimensions and patterns require a drawing-level review with the exact sensing device.
| Product format | Supplier-listed example | Pattern / pole data | Engineering note |
|---|---|---|---|
| Precision short scales | L15 × W6 × H1.3 mm; L63 × W8 × H1.5 mm; other custom lengths | Pole pitches include 1.0, 1.27, 2.0 and 2.54 mm | One L63 example includes an S/N/S reference pattern. |
| Long precision scales | L870 × W10 × H1.5 mm; L1380 × W10 × H1.5 mm | TR50 examples | Confirm straightness, mounting and readhead compatibility. |
| Large incremental ring | OD202.4 × ID180 × 9 mm | 64 pole pairs TR50; 160 pole pairs TR20; 320 pole pairs TR10 | Supplier documentation also lists OD120 × ID90 mm rings with 1.0 or 2.0 mm pole pitch. |
| Dual-track absolute ring | OD30 × ID11 mm | Main pole pitch 1.28 or 1.50 mm; axial 32/31 pole pairs; radial 64/63 pole pairs | For absolute encoder architectures using corresponding iC-Haus devices; confirm exact device matching. |
Ring and short-scale examples are not a complete catalog. Supplier material describes greater-than-1 mm mounting-gap capability for certain ring products; the allowable gap must be confirmed for the exact ring, readhead and installation.
Inatech readhead documentation describes non-contact measurement, an integrated conversion module and digital output. Environmental robustness still depends on the complete installation.

Incremental readheads provide A/B quadrature signals. Supply voltage, output circuit, cable and controller compatibility must be checked by model.
Scale straightness, ring runout, mounting gap, alignment and thermal expansion influence signal quality and repeatability.
Supplier material describes resistance to dust, vibration and contamination and low sensitivity to dust and ferrous particles. Do not infer an IP rating unless it is stated for the selected model.
Magnetic encoding is attractive where a non-contact scale and readhead can be integrated into the mechanism and where the environment makes an exposed optical scale less convenient.
Rolled or precision short scales for travel feedback, with the machine structure controlling alignment and the selected readhead defining the interface.
Incremental or dual-track rings for compact rotary feedback; ring geometry and bearing/runout conditions must be reviewed together.
Linear or rotary position feedback where dust, oil mist or routine contamination requires a robust, non-contact measuring concept.
Magnetic carriers, rings, holders and structural mounting details can be reviewed as a drawing-based component package.
Drawings and operating conditions let us discuss the magnetic circuit and mechanical structure together. If some items are unknown, mark them as open rather than guessing.
No. Magnetization accuracy describes the scale pattern. Complete-system accuracy also depends on the readhead, electronics, interpolation, installation, alignment, runout and thermal conditions.
The documented readhead output described here is incremental A/B quadrature. Absolute operation requires a suitable absolute scale/ring pattern and compatible encoder electronics; confirm the exact architecture.
Yes. Magnetic rings or scales can be discussed together with carriers, hubs, brackets and other drawing-based mounting components.
Start with the exact readhead or encoder device and its supported pole pitch, then review speed, target output, installation space and mechanical tolerances. Pole pitch alone does not define system resolution.
Send your drawing, application conditions and target integration level. XAK will respond within 24 hours.
Contact →Request a Quote